Critical Care

  • Patient range : Adult, pediatric, neonate
  • NIBP Measurement method : Oscillometric
  • NIBP Measurement range : 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg)
  • Temperature Range : 37°C to 42°C
  • Temperature Accuracy : ± 0.5°C
  • Warm-up Time : < 45 s (20°C to 36°C)
  • Temperature Range : 37°C to 42°C
  • Temperature Accuracy : ± 1.0°C
  • Warm-up Time : < 45 s (20°C to 36°C)
  • Display : 12.1” LCD display
  • Ultrasound frequency : 1024 (1 ± 10%) kHz
  • Max output intensity : < 10 MW/cm2
  • Display : 7-inch screen
  • Waveform : Biphasic
  • Manual with Sync mode : 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
  • Waveform : Biphasic
  • Energy Sequence : 150 J, 200 J
  • Analysis Time : 9 seconds
  • Display : OLED 160 x 128 dot matrix display
  • Storage : Built-in TF card storage for up to 2 GB
  • Standard Sensitivity : 10 mm/mV ± 5%
  • Control System : Air-temp control, Skin-temp control & Humidity control
  • Display : LED display
  • Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)
  • Control System : Air-temp control & Skin-temp control
  • Display : LED display
  • Air Temperature Control range : 25°C ~ 37°C (Override : 37°C ~ 39°C)
  • Control System : Air-temp control
  • Display : LED display
  • Air Temperature Control range : 25°C ~ 37°C
  • Channel : Single channel infusion
  • Volume (VTBI) : 1 ml ~ 9999.9 ml ( 0.1 ml increment)
  • Accuracy : Flow rate: ≤ ± 3 %
    Mechanical: ≤ ± 2 %
  • Channel : Single channel infusion
  • Infusion Volume : 0 ml ~ 9999 ml ( 0.1ml increment)
  • Infusion Rate : 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment)
  • Tidal Volume : 20 ml ~ 500 ml
  • Standard Ventilation Mode : VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH
  • Application : Adult/ Pediatric Invasive
  • Tidal Volume : 10 ml ~ 300 ml
  • Standard Ventilation Mode : CMV, IMV, CPAP, Manual
  • Application : Pediatric
  • Tidal Volume : 20 ml ─ 2500 ml
  • Configurations : Trolley or Ceiling Pendant
  • Respiratory Rate : 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV)
    4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
  • Control System : Microprocessor based temperature control system
  • Control Modes : Preheat, Manual and Skin-temp mode
  • Manual : Heater output : 0-100%, 10% increments
  • Vital Parameters :
    Type AType BType C
    4 Parameters (NIBP,SpO2, PR, Temp)3 Parameters (SpO2, PR, Temp)3 Parameters (NIBP, SpO2, PR)
  • Display : 240 x 320 dot matrix colour TFT
  • NIBP Measurement range : Adult: 30-255 mmHg
    Paediatric: 30-160 mmHg 
  • Vital Parameters : 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP)
  • NIBP Measurement range : Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg
  • NIBP Mode : Manual, Auto
  • Standard Parameter : 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR
  • Patient Groups : Neonate, Pediatric, Adults
  • Trace : 9 waveform (ECG,SpO2, RESP)
  • Light Source : 8 Blue LED lights
  • Wavelength : 450 to 475nm
  • LED Lamp-life : 1,00,000 hours
  • Type : Adult
  • Stroke volume : 800 ml
  • Resuscitator volume : 1630 ml
  • Type : Pediatric
  • Stroke volume : 350 ml
  • Resuscitator volume : 680 ml
  • Type : Neonatal
  • Stroke volume : 150 ml
  • Resuscitator volume : 250 ml
  • KVO Rate : 0.1 – 5ml/h (steps : 0.1ml/h)
  • Injection Compliance : Adaptable for 5 syringe sizes
  • Preset Volume Range : 0.1 ml – 1999.9 ml
  • Channel : Single channel infusion
  • Volume (VTBI) : 0 ml – 9999 ml
  • Injection Compliance : Adaptable for 6 syringe sizes
  • Channel : Dual channel infusion
  • Volume (VTBI) : 0.1 ml – 1999.9 ml
  • Injection Compliance : Adaptable for 10 syringe sizes
  • Tidal Volume : 0 ml – 1500 ml
  • Gas Supply : O2, 0.28 to 0.6 MPa
  • Ventilation Modes : A/C, SIMV, SPONT, Manual, VCV+SIGH